Skip to main content
Skip table of contents

Meter

Overview

Peak and RMS meter module

Discussion

The Meter module provides a flexible level meter that can operate in several modes. The module has a single multichannel input and separately meters each channel. The meter can be configured to conform to IEC 60280-10 (peak meters) and IEC 60280-17 (VU Meter) specifications. The meterType parameter is used to configure the module as follows.

meterType

Description

Attack Time (msec)

Release Time (msec)

Comments

0

FastPeakSample

5

1087

Peak meter: IEC 60280-10 "fast mode"

1

SlowPeakSample

10

1450

Peak meter: IEC 60280-10 "slow mode"

2

VUMeterSample

65

65

IEC 60280-17 standard "VU meter"

3

CustomSample

user

user

Set the attackTime and releaseTime from a Matlab script

4

InstantSample

0

0

Instantaneous (attack and release times of 0 msec). The meter value equals the last value in each block.

16

FastPeakBlock

5

1087

Computationally efficient peak meter: IEC 60280-10 "fast mode"

17

SlowPeakBlock

10

1450

Computationally efficient peak meter: IEC 60280-10 "slow mode"

18

VUMeterBlock

65

65

Computationally efficient IEC 60280-17 standard "VU meter"

19

CustomBlock

user

user

Computationally efficient custom meter. Set the attackTime and releaseTime from a Matlab script

20

InstantBlock

0

0

Computationally efficient instantaneous meter (attack and release times of 0 msec). The max abs value of each block is returned without time constants.

In meterTypes 0 to 4, the peak attack and release are performed on a sample-by-sample basis in the envelope follower. In meterTypes 16 to 20, the peak absolute value for the entire input block is found and this one value is passed through the envelope follower.

Type Definition

CODE
typedef struct _ModuleMeter
{
    ModuleInstanceDescriptor instance;            // Common Audio Weaver module instance structure
    INT32 meterType;                              // Operating mode of the meter. Selects between peak and RMS calculations. See the discussion section for more details.
    FLOAT32 attackTime;                           // Attack time of the meter. Specifies how quickly the meter value rises.
    FLOAT32 releaseTime;                          // Release time of the meter. Specifies how quickly the meter decays.
    FLOAT32 attackCoeff;                          // Internal coefficient that realizes the attack time.
    FLOAT32 releaseCoeff;                         // Internal coefficient that realizes the release time.
    FLOAT32* value;                               // Array of meter output values, one per channel.
} ModuleMeterClass;

Variables

Properties

Name

Type

Usage

isHidden

Default value

Range

Units

meterType

int

parameter

0

18

Unrestricted

attackTime

float

derived

1

65

0:1000

msec

releaseTime

float

derived

1

65

0:10000

msec

attackCoeff

float

derived

1

0.02336

Unrestricted

releaseCoeff

float

derived

1

0.02336

Unrestricted

value

float*

state

0

[1 x 1]

-60:10

linear

Pins

Input Pins

Name: in

Description: audio input

Data type: float

Channel range: Unrestricted

Block size range: Unrestricted

Sample rate range: Unrestricted

Complex support: Real

Scratch Pins

Channel count: 1

Block size: 32

Sample rate: 48000

MATLAB Usage

File Name: meter_module.m

CODE
 M=meter_module(NAME)
 Creates a meter module for use in the Audio Weaver environment.
 The module has a single multichannel input pin.  

 Arguments:
    NAME - name of the module.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.